close
Filter By
Brand
- A & M INDUSTRIES622
- ACE PUMP CORPORATION187
- ACE ROTO-MOLD MFG INC385
- AR NORTH AMERICA83
- BANJO CORPORATION1092
- C & R SUPPLY1130
- COX REELS4
- DETHMERS MANUFACTURING45
- DOSATRON22
- DUO LIFT3
- DURA PRODUCTS21
- FILL-RITE19
- FLOWSERVE PUMP CORP52
- GREENLEAF TECHNOLOGIES30
- HANNAY REELS INC.18
- HD HUDSON MFG CO5
- HYPRO LLC442
- JOHN BLUE CO214
- NORWESCO, INC192
- RAVEN IND (NW-9348)672
- SPRAY TARGET7
- SPRAYING SYSTEMS CO.876
- SQUIBB TAYLOR INC10
- TEEJET TECHNOLOGIES52
- TERREMAX43
- TEXAS INDUSTRIAL REMCOR33
- TOTALLY TUBULAR22
- UDOR U.S.A.41
- WILGER INC.130
HD HUDSON MFG CO, FILL-RITE - TOTALLY TUBULAR
46 items
**FINGER TUBE; 3000 KINZE
500 TT301
Kinze Starter Fertilizer Placement Tube Part #TT-301 (Patented) This simple yet effective design is totally protected by the disc blades, so rocks should not be an issue. The 1/8" wall 3/8" stainless tube will easily outlast the disc scraper. The optional seed bounce flap closes the opening between the disc openers assuring correct seed placement by eliminating seed bounce and ricochet. Key Benefits Starter Fertilizer application deeper in the soil profile Instant root uptake for early plant health Maintenance free Install hose clamp around the shank and placement tube, just above the inside disc scraper. This will hold the tube against the bottom of the shank. Installation Instructions: Remove depth gauge wheels and disc openers, making sure to note correct shim placement. Find the 1/4" casting hole in the shank. This is approximately 1" above and 2" forward of the threaded disc opener attachment hole. Drill this hole out to 9/32 Lift the placement tube up into place and insert the enclosed 1/4" cap screw thread it into the weld nut on placement tube mounting tab. Use the enclosed hose clamp to secure tube firmly to scraper as shown in picture above. Tighten cap screw Attach zip tie in existing hole in planter to tube as shown in picture. Reinstall disc openers. The 6mm tubing is provided for producers who may experience plugging issues due to applying a lower rate of fertilizer. Push this tubing up the bottom side of the fertilizer tube, leaving approximately 1/4" sticking out the bottom. (You may need to cut the plastic tubing off after pushing it up as far as you can.) This will create back-pressue at the bottom of the tube. Due to the variances in Kinze planters, two sizes of bolts have been provided. 1" and 7/8"; use the bolt that best fits your planter. Kinze fertilizer tubes were not meant to be used on planters that are planting deeper than 2 inches. Producers planting deeper than 2 inches may experience rubbing issues on areas of the tube. Recommend replacing disc openers when you put our fertilizer tubes on.
**ROW UNIT, GREAT PLAINS
500 TT400
Great Plains planter Starter Fertilizer Placement Tube Part #TT-400 This simple yet effective design is totally protected by the disc blades, so rocks should not be an issue. The 1/8" wall 3/8" stainless tube will easily outlast the disc scraper. The optional seed bounce flap closes the opening between the disc openers assuring correct seed placement by eliminating seed bounce and ricochet. Key Benefits Starter Fertilizer application deeper in the soil profile Instant root uptake for early plant health Maintenance free Installation Instructions: 1. Remove depth gauge wheels and disc's, taking note of shim placement 2. Remove factory seed tube guard remove disc guard bolt on the right side of the row unit (standing behind) 3. Lift TT-400 up into position on row unit 4. Align roll pin holes and install roll pins 5. Re-Install seed tube 6. Re-Install disc openers taking care to get the correct shim placement 7. Re-Install depth gauge wheels Recommend replacing disc openers when you put our fertilizer tubes on.
**FERTILIZER TUBE KINZE 4000 SERIES
500 TT401
This simple yet effective design is totally protected by the disc blades, so rocks should not be an issue. The 1/8" wall 3/8" stainless tube will easily outlast the disc scraper. The optional seed bounce flap closes the opening between the disc openers assuring correct seed placement by eliminating seed bounce and ricochet. Key Benefits Starter Fertilizer application deeper in the soil profile Instant root uptake for early plant health Maintenance free The Elbow Coupler shown here is available for 3/8, 1/4, & 5/16 size hose. This is an added option available with this tube. Due to the bracket right above the top of the fertilizer tube, this Elbow Coupler works very well for plumbing your Kinze planter. Remember to order Elbow couplers with this tube. See 'Flaps and Fittings' on the Products page. Remove depth gauge wheels & disc openers, making sure to note correct shim placement. Remove seed tube guard. Install new TT-401 fertilizer tube. Bend centering tab against row shank, using a rubber mallet as necessary. The 6mm tubing is provided for producers who may experience plugging issues due to applying a lower rate of fertilizer. Push this tubing up the bottom side of the fertilizer tube, leaving approximately 1/4" sticking out the bottom. (You may need to cut the plastic tubing off after pushing it up as far as you can.) This will create back-pressure at the bottom of the tube. Recommend replacing disc openers when you put our fertilizer tubes on.
*SITE CAP ASSEMBLY
139 400H1401
*KIT, 800 SERIES METER
139 KTG2541
**2 GAL. PROFESSIONAL PUMP-UP SPRAYER
500 H90162
**CIH 1200 BELOW SEED FERT TUBE
500 TT125
**FERT TUBE/BRKT 2150 CASE PACKING WHEEL
500 TT321
**WHITE 9000 SERIES CLOSING WHEEL TUBE
500 TT390